  1. Hand Scanners
  2.  
  3.  
  4. Many hand scanners are now supported by PC Paintbrush IV Plus. Often
  5. their use with Paintbrush differs quite a bit from the bundled
  6. software that came with the hand scanner. This is because
  7. Paintbrush uses DOS Device Drivers to interface all types of
  8. scanners, not just hand scanners. Also, Paintbrush was primarily
  9. designed to support scanners that are programmable and under
  10. the complete control of Paintbrush. Because of the human
  11. element involved with hand scanning, Paintbrush must attempt to
  12. deal with additional restrictions.
  13.  
  14. This document has been compiled to help explain and perhaps
  15. eliminate some of the problems you might encounter. Since ZSoft
  16. scanner device drivers work with all ZSoft scanning products,
  17. this document is of a generic nature, although PC Paintbrush IV
  18. Plus is presumed for the sake of simplicity.
  19.  
  20. If you find that the image produced by our hand scanner
  21. driver is not as good as the image you can produce with the
  22. software that was bundled with your hand scanner, you are
  23. advised to use that software to scan, then import the image for
  24. editing with Paintbrush.
  25.  
  26. To use a hand scanner, first install the driver as usual, making
  27. sure that the ZSoft scanner driver comes after the EMS driver in
  28. your CONFIG.SYS. Make sure that all parameters are set up
  29. correctly on the command line. Most hand scanner drivers will
  30. operate more than one type of hand scanner from the same
  31. manufacturer. 
  32.  
  33. Reboot the computer to install the driver. A message will be
  34. displayed during the boot process that identifies the driver
  35. and additional information about the hand scanner installation.
  36. Note that the scanner driver will state what EMS is available.
  37.  
  38. Since the available hand scanners can only scan in black and
  39. white, Paintbrush should be run in a two-color mode. This saves
  40. memory because Paintbrush must allocate a scanning buffer for
  41. each plane or color. In the case of 16-color, the scanning
  42. buffer will take up four times as much memory as it will in a
  43. two-color mode. So if you try to scan while in color mode, you
  44. will run out of memory four times as fast. 
  45.  
  46. This may not seem to be a problem if you have plenty of EMS memory, 
  47. but a 16-color mode will generate .PCX files four times as large 
  48. as necessary. So run PBSETUP.EXE and chose an appropriate two-color 
  49. mode to scan with. Remember that you can always read your .PCX files into 
  50. a color mode later.
  51.  
  52. Now you are ready to run Paintbrush. Paintbrush will initialize
  53. the scanner when your choose the File Scan Image command. (If the driver is
  54. not present there will be a 'Scanner Not Available' message.
  55. Check your CONFIG.SYS file.) The hand scanner light should turn
  56. on for a second. This is to let you know that it is properly
  57. installed at the right port address. 
  58.  
  59. When Paintbrush is ready for use, you can look at Statistics
  60. on the Help menu to determine what particular scanner type
  61. the device driver is set up to operate. Some hand scanner
  62. drivers support many different hand scanners, so these will display a
  63. different message for each different setup. This is to confirm
  64. that you have correctly set up the hand scanner driver. 
  65.  
  66. Choose Scan from the Scan menu. The scanning dialog box appears. 
  67.  
  68. Some of the functions for your scanner may not be displayed in the dialog box. This is because the controls for these functions are on the hand scanner
  69. itself.
  70.  
  71. Make any adjustments you want to the hand scanner. Note 
  72. the resolution that you choose on the hand scanner must match
  73. the setting in the dialog box. For instance, if you want a 100
  74. dpi scan, you must set the scanner to that resolution and type in
  75. 100 dpi in Paintbrush's dialog box as well. Mismatch of resolutions 
  76. can severly distort a hand scanner image.
  77.  
  78. The Paintbrush dialog box may not show an option for Brightness
  79. or Dithering, even if you scanner supports them. This is because
  80. Brightness and Dither are usually set on the hand scanner
  81. itself.
  82.  
  83. Once options are set, you click on 'OK' and proceed to
  84. the scan sizing dialog box. Here you set the size of the image
  85. to scan. 
  86.  
  87. There are several things that are useful to know. Image
  88. width is limited by the size of the scanner, but image length is
  89. limited to available memory. Hand scanner drivers allow a
  90. maximum of fourteen (14) inches for a scan if enough EMS is
  91. available.
  92.  
  93. The scanning window is treated differently with hand scanners
  94. than it is with flatbed or sheet-fed scanners. The scanning
  95. window always starts in the upper lefthand corner and is as wide 
  96. as the maximum scanning width of the hand scanner. 
  97.  
  98. You can set the left and right margins. However, if the right margin
  99. is greater than the scan length, the driver will 'clip' the
  100. width to the maximum scanner length. Also if you ses the
  101. left margin greater than the maximum width of the hand scanner,
  102. the driver will not be able to return any information
  103. because the window is outside the scanner's range.
  104.  
  105. Top margins may be set, but this is a redundant option; it is
  106. assumed that the hand scanner will be placed at the top of the
  107. area to scan. The bottom margin is very important because this
  108. determines the scan length.
  109.  
  110. To set the hand scanner window, drag the mouse down and to
  111. the right in the window sizing box. Click the right mouse button 
  112. to set the size. If the width is too great the driver will
  113. 'clip' it to the maximum length. If the length is too great,
  114. then Paintbrush will display an error message.
  115.  
  116. There are two variations of error messages that relate to 
  117. memory shortage. With only DOS memory and no EMS, Paintbrush may
  118. display an 'Image Too Big' message. If there is not enough EMS, a
  119. 'Scan Open Error', will be displayed. In either event there are
  120. two things that can be done: either scan a smaller area or
  121. switch to a lower resolution.
  122.  
  123.  
  124.  
  125. **  NOTE: While scanning, you will not see the image appear on
  126. screen until AFTER the full scan has been completed **.
  127.  
  128.  
  129.  
  130.  The successful use of hand scanners require some additional
  131. considerations:
  132.  
  133. Hand scanners are very memory dependent. All ZSoft scanner
  134. device drivers will utilize any available EMS memory. However,
  135. the drivers require LIM 4.0 or equivalent EMS drivers to work
  136. with Windows (TM). If there is no EMS, the driver will use
  137. the available DOS memory to scan into, or save the scanned image to,
  138. the hard disk.
  139.  
  140. Since the user provides the scanning motion with a hand scanner,
  141. the image quality is dependent on the speed at which the hand
  142. scanner is moved. A steady slow movement over the picture 
  143. you are scanning is recommended for the best scans. If a scan is too fast,
  144. the image will appear squashed, and the distance that is scanned
  145. will be more than that chosen in the dialog box for the scanning
  146. window.
  147.  
  148. It's easy to figure the maximum size image available under a
  149. given resolution: Size in Bytes = DPI * Width of Scan * DPI *
  150. Length of Scan / 8 Pels per Byte
  151.  
  152. So a 200 dpi scan, 4 inches wide and 3 inches long requires:
  153.  
  154. 200 * 4 * 200 * 3 / 8 = 60000 bytes or 60Kbytes
  155.  
  156.  
  157.  
  158. Hand scanner drivers will work without EMS, but in a restricted manner.
  159. Mainly, the scanned image must be reduced in size. For
  160. instance, on most 640 K machines, typical scanned image sizes
  161. are:
  162.  
  163. Resolution Image Size DOS Memory Used
  164.  
  165. 200 dpi 4" X 6"    120K
  166.  
  167. 300 dpi 4" X 3"    120K
  168.  
  169. 400 dpi 4" X 1.5"    120K
  170.  
  171. Image quality is very dependent on scanning speed. Scanning too
  172. fast will squash the image. Some hand scanners have a scan overrun 
  173. light that goes out if you are scanning too fast. When
  174. scanning, you can stop scanning, release the scan switch
  175. momentarily and the overrun light will come back on.
  176.  
  177. If you are using 386MAX Version 4.06 or less, it may be
  178. impossible to use the scanner. Qualitas has fixed the problem
  179. in Version 4.07.
  180.  
  181. Paintbrush may save buffers to the hard disk during the scan. 
  182. When the disk is accessed, scan lines can be lost, resulting in
  183. gaps in the image. The entire scan may be scanned to Expanded
  184. Memory and then read back as required, greatly reducing the
  185. chance of losing scan lines.
  186.  
  187. You will find that if you do not scan when the hard disk light
  188. is on (i.e., when the disk is being accessed), the image
  189. will be better.
  190.  
  191. LIMITATIONS:
  192.  
  193. THESE DRIVERS ARE GAMMA RELEASE LEVEL. THIS MEANS THEY
  194. WORK WELL ENOUGH TO PASS OUR TESTING DEPARTMENT. HOWEVER, WITH
  195. THE MYRIAD OF PC HARDWARE AVAILABLE ON THE MARKET TODAY, THERE
  196. MAY BE SOME PROBLEMS REMAINING.
  197.  
  198. WE DO KNOW THAT THESE DRIVERS (VERSION 4.01) WILL PRODUCE
  199. SEAMLESS IMAGES WITH LIM 4.0 EMS AND AN 'AT' COMPUTER, WITH THE